Integrated Radiation Shield
| Part Number | Description | Product Details | Additional Accessories | Link |
| DSC404F1A59.000-00 | Temp Range (℃): -150 to 1000 (Type P), Not ASC Compatible, Shape: n/a | Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A70.000-00 | Temp Range (℃): -150 to 700 (Type E), Not ASC Compatible, Shape: Standard | Inert: -150 to 700; Oxidizing: -150 to 500; Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A79.000-00 | Temp Range (℃): -150 to 700 (Type E), Not ASC Compatible, Shape: Octagonal | Octagonal design; Inert: -150 to 700; Oxidizing: -150 to 500; Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A71.000-00 | Temp Range (℃): -150 to 800 (Type K), Not ASC Compatible, Shape: Standard | Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A77.000-00 | Temp Range (℃): -150 to 800 (Type K), Not ASC Compatible, Shape: Octagonal | Octagonal design; Inert: -150 to 800; Oxidizing: -150 to 500; Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A72.000-00 | Temp Range (℃): 25 to 1650 (Type S), Not ASC Compatible, Shape: Standard | Includes 2x PtRh crucible GB399205 & lid GB399860; 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 | |
| DSC404F1A54.000-00 | Temp Range (℃): 25 to 1650 (Type S), Not ASC Compatible, Shape: Octagonal | Octagonal design. Includes 2x PtRh crucible GB399205 & lid GB399860, 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 | |
| DSC404F1A78.000-00 | Temp Range (℃): 25 to 1650 (Type S), Not ASC Compatible, Shape: Octagonal | Octagonal design. Includes 2x PtRh crucible GB399205 & lid GB399860; 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 | |
| DSC404F1A75.000-00 | Temp Range (℃): -150 to 1000 (Type P), ASC Compatible, Shape: n/a | Includes 2x PtRh crucible GB399205 & lid GB399860; 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 | |
| DSC404F1A66.000-00 | Temp Range (℃): -150 to 700 (Type E), ASC Compatible, Shape: n/a | Inert: -150 to 700; Oxidizing: -150 to 500; Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A74.000-00 | Temp Range (℃): -150 to 800 (Type K), ASC Compatible, Shape: n/a | Inert: -150 to 800; Oxidizing: -150 to 500; Includes 2x Al2O3 crucible GB399972 & lid GB399973 | GB399972, GB399973 | |
| DSC404F1A73.000-00 | Temp Range (℃): 25 to 1650 (Type S), ASC Compatible, Shape: n/a | Includes 2x PtRh crucible GB399205 & lid GB399860; 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 | |
| DSC404F1A76.000-00 | Temp Range (℃): 25 to 1750 (Type B), Not ASC Compatible, Shape: n/a | Includes 2x PtRh crucible GB399205 & lid GB399860; 2x Al2O3 crucible GB399972 & lid GB399973 | GB399205, GB399860, GB399972, GB399973 |