Part Number | Description | Details | Additional Accessories | Link |
6.220.10-62.1.00 | Type P, No Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Sample support made of Al2O3, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-63.1.00 | Type P, No Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For large samples, sample supports made of Al2O3, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-61.1.00 | Type P, No Radiation shield included, Platinel Sample Support Material, 9 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-62.0.00 | Type P, Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Sample support made of Al2O3, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-63.0.00 | Type P, Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For large samples, sample supports made of Al2O3, radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-61.0.00 | Type P, Radiation shield included, Platinel Sample Support Material, 9 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, for large samples, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-60.0.00 | Type P, Radiation shield included, Platinel Sample Support Material, 7 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-60.1.00 | Type P, No Radiation shield included, Platinel Sample Support Material, 7 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating,without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-65.1.00 | Type P - Protected, No Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Standard sample carrier with closed stuck head plate, particularly suitable for corrosive media, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-66.1.00 | Type P - Protected, No Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For crucible up to an outer diameter of 9 mm, with protected thermocouple, particulary suitable for corrosive media. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
6.220.10-65.0.00 | Type P - Protected, Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | |||
6.220.10-66.0.00 | Type P - Protected, Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For crucible up to an outer diameter of 9 mm, with protected thermocouple, particulary suitable for corrosive media, including radiation shield and crucible made of Al2O3 with ø 8 mm (0.3 ml, order no. NGB803698). TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00, NGB803698 |
TGA 209 - Al2O3 Sample Carrier
Log in with approved account

Contract Testing
Our Thermal Analysis Applications Laboratories are a experienced partner for thermal analysis issues. Our involvement in your projects begins with precise and careful sample preparation and continues through profound examination and interpretation of the measurement results.
Learn More