| Part Number | Description | Details | Additional Accessories | Link |
| 6.220.10-62.1.00 | Type P, No Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Sample support made of Al2O3, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-63.1.00 | Type P, No Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For large samples, sample supports made of Al2O3, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-61.1.00 | Type P, No Radiation shield included, Platinel Sample Support Material, 9 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating, without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-62.0.00 | Type P, Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Sample support made of Al2O3, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-63.0.00 | Type P, Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For large samples, sample supports made of Al2O3, radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-61.0.00 | Type P, Radiation shield included, Platinel Sample Support Material, 9 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, for large samples, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-60.0.00 | Type P, Radiation shield included, Platinel Sample Support Material, 7 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-60.1.00 | Type P, No Radiation shield included, Platinel Sample Support Material, 7 mm Max Crucible Outer Diameter | Higher sensitivity for c-DTA®, with SiO2 coating,without radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-65.1.00 | Type P - Protected, No Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | Standard sample carrier with closed stuck head plate, particularly suitable for corrosive media, including radiation shield. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-66.1.00 | Type P - Protected, No Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For crucible up to an outer diameter of 9 mm, with protected thermocouple, particulary suitable for corrosive media. TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00 | |
| 6.220.10-65.0.00 | Type P - Protected, Radiation shield included, Al2O3 Sample Support Material, 7 mm Max Crucible Outer Diameter | |||
| 6.220.10-66.0.00 | Type P - Protected, Radiation shield included, Al2O3 Sample Support Material, 9 mm Max Crucible Outer Diameter | For crucible up to an outer diameter of 9 mm, with protected thermocouple, particulary suitable for corrosive media, including radiation shield and crucible made of Al2O3 with ø 8 mm (0.3 ml, order no. NGB803698). TG 209 F1 Libra® – All instruments; TG 209 F1 Iris® – As of instrument No. 220 10 077*; TG 209 F3 Tarsus® – As of instrument No. TGA209F3A-0010-L* | 6.220.10-60.2.00, 6.220.10-60.3.00, NGB803698 |