Image coming soon

DIL 402 Expedis Supreme - Sample Holder Kit

Write a Review

Max Length:  52 mm

Part Number Description Product Details Max Temp (℃)
DIL40200A50.000-00 Single Al2O3 12mm Sample ø - 4, 6, 8 mm sample supports included, Type S Thermocouple Highly sintered Al2O3. Allowing for samples of various diameters to be measured over a wide temperature range. 1680°C
DIL40200A52.000-00 Single Fused Silica 19 mm Sample ø - 6, 12.7, 15 mm sample supports included, Type K thermocouple Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. 1100°C
DIL40200A68.000-00 Single Graphite 6 mm Sample ø - 4, 6, 8 mm sample supports included, Type W Thermocouple Thermocouple W3%Re-W25%Re. Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. The longitudinal temperature distribution is optimized to the available standard samples of maximum 25 mm.  2000°C
DIL40200A78.000-00 Single Graphite5 6 mm Sample ø - 4, 6 mm sample supports included, Type W Thermocouple With sheathed W3%Re-W25%Re thermocouple; sheath made of molybdenum. Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. The longitudinal temperature distribution is optimized to the available standard samples of maximum 25 mm.  2000°C
DIL40200A72.000-00 Single Graphite 19 mm Sample ø - 6, 12.7, 15 mm sample supports included, Type W Thermocouple Thermocouple W3%Re-W25%Re. Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. The longitudinal temperature distribution is optimized to the available standard samples of maximum 25 mm.  2000°C
DIL40200A77.000-00 Single Graphite 8 mm Sample ø - 4, 6, 8 mm sample supports included, Type W thermocouple Pyrometer, thermocouple W3%Re-W25%Re. Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. The longitudinal temperature distribution is optimized to the available standard samples of maximum 25 mm.  2800°C
DIL40200A55.000-00 Single Graphite 19 mm Sample ø - 6, 12.7, 15 mm sample supports included, Type W Thermocouple Pyrometer, thermocouple W3%Re-W25%Re. Includes holding tube with metal bush, slide, pushrod, thermocouple holding segment, thermocouple and a set of sample supports. The longitudinal temperature distribution is optimized to the available standard samples of maximum 25 mm.  2800°C
Contract Testing

Contract Testing

Our Thermal Analysis Applications Laboratories are a experienced partner for thermal analysis issues. Our involvement in your projects begins with precise and careful sample preparation and continues through profound examination and interpretation of the measurement results.

Learn More
Have Questions?

Have Questions?

Our experts are happy to help you.

Contact Us